Description aqua pulse 1l; System module pulse Pulse value: 1 liter Pulse width: 50 ms Switching capacity: max. 220 mA, 48 V DC Cable length, fixed: 1.5 m Supply: 3 V lithium battery Battery life: 15 years Re-running detection with compensation Degree of protection: IP 68
Code intérieur FBR168827
Poids 1

Vous pouvez nous contacter en France dans le but d'obtenir un devis avec prix et délai de livraison si vous cherchez le produit Integra Metering AG (formerly Aquametro) - 80113 aqua pulse 1l; System module pulse Pulse value: 1 liter Pulse width: 50 ms Switching capacity: max. 220 mA, 48 V DC Cable length, fixed: 1.5 m Supply: 3 V lithium battery Battery life: 15 years Re-running detection with compensation Degree of protection: IP 68 . Nous pouvons également vous proposer des produits d'autres marques et fabricants avec les meilleurs conditions de vente. Grâce à notre réseau de partenaires en Allemagne et à l'étranger, nous essayons de vous donner des prix compétitifs et des délais de livraison courts pour Integra Metering AG (formerly Aquametro) - 80113 aqua pulse 1l; System module pulse Pulse value: 1 liter Pulse width: 50 ms Switching capacity: max. 220 mA, 48 V DC Cable length, fixed: 1.5 m Supply: 3 V lithium battery Battery life: 15 years Re-running detection with compensation Degree of protection: IP 68 . Mais notre entreprise n’est pas un distributeur officiel sous contrat.

Les marques et les produits indiqués sur notre site sont des exemples à tittre informatif. Nous respectons strictement les droits de propriété privée des constructeurs respectifs.

Notre société n'est pas un distributeur agréé. Tous droits sont réservés aux fabricants et à leurs partenaires officiels.

Mêmes produits de Integra Metering AG (formerly Aquametro)

83565 IN0,1H/RW/RD 25

ARD Construction Group DOMINO® - Reguliergetriebe - pulseur pour des températures élevées NAMUR / DIN 19234 - Rouleau 6 chiffres, pouvant tourner. - bague de verrouillage avec couvercle

89206 TOPAS PMW - OBSOLETE

Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls

89216,TOPAS PMW - OBSOLETE

Nominal flow: Qn = 10; Nominal diameter: DN 40; Reporting: 1 liter of 1impuls water meter

89224 TOPAS PMWF - OBSOLETE

Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls

89244 TOPAS PMWF - OBSOLETE

Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls

89252 TOPAS PMWF - OBSOLETE

Nominal flow: Qn = 10; Nominal diameter: DN 40; Reporting: 1 liter of 1impuls

89270;TOPAS PMWS - OBSOLETE

Nominal flow: Qn = 10; Nominal diameter: DN 40; Reporting: 1 liter of 1impuls

89629 TOPAS PMG - OBSOLETE

Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls

89642 TOPAS PMGS - OBSOLETE

Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls

89654 TOPAS PMGF - OBSOLETE

Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls

89771 VZO 8 OEM-RE0,0125

(CONTOIL ® fuel oil meters Reed pulser Pulse value 12.5 ml Nominal diameter: 8 mm With female thread for Kupferrohrverschr. 1/4 " Nominal pressure: PN 25 Maximum permissible temperature: 60 ° C Mounting position: horizontal / vertical Largest flow Qmax. 200 l / h In continuous operation: 135 l / h Error of measurement: 4-200 l / h ± 1% of measured value Pulse value: 0.0125 l)

92047 VZO 20 RC 130/16

VZO 15... 40 avec filetage, PN 16

92049 VZO 20 FL 130/25

Fuel-oil fuel meter

92059 / VZO 25 FL 130/25

compteur d'huile

93533

[AMBUS IS M-Bus Impulssammler 1 Impulseingang 2 Leiter M-Bus Schnittstelle 2 Leiter Energieversorgung aus AMBUS ZS oder Net]

94249

PMG 32-RH1 6.0_260_1 G1 / 4 multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 260 mm Mounting position: horizontal Temperature: max. 130 ° C Nominal pressure: PN 16 Minimum flow qi: 0,075 m³ / h Continuous flow qp: 6 m³ / h Maximum flow qs: 12 m³ / h Kvs-value: 12.7 m³ / h Pressure loss at qp: 0,22 bar Pulse value: 1 liter / pulse Environmental class C according to EN 1434 no inlet: 0 x DN 32 no outlet flow: 0 x DN 32 Approval MI-004

94252 PMGF 32-RH1 5.0_150_1 1/4"

Size: DN 32 with thread 1 1/2 "(for screw 1 1/4") Nominal pressure: PN 16 bar length: 150 mm Mounting position: vertical falling temperature max .: 130 ° C Maximum flow qs: 6.3 m3 / h Nominal flow qp: 5 m3 / h minimum flow qi: 0.1 m3 / h pulse value: 1 l Smallest readable amount: 0.1 l registrable: 99,999 m3 measuring principle: multi-jet impeller, dry running With CE marking

94255

PMGS 32-RH1 5.0_150_1 G1 / 4 multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 150 mm Mounting position: vertical ascending Riser counter Temperature: max. 130 ° C Nominal pressure: PN 16 Minimum flow qi: 0.1 m³ / h Continuous flow qp: 5 m³ / h Maximum flow qs: 6,3 m³ / h Kvs-value: 13.6 m³ / h Pressure loss at qp: 0,14 bar Pulse value: 1 liter / pulse Environmental class C according to EN 1434 no inlet: 0 x DN 32 no outlet flow: 0 x DN 32 Approval MI-004

94525 50 50_200

MeiStream RUBIN Kaltwasserzähler Nenngrösse: DN 50 Flanschanschluss: EN 1092-1 Nenndruck: PN 16 bar Baulänge: 200 mm Einbaulage: horizontal/vertikal Schutzart: IP 68 Temperatur max.: 50°C Überlastungsdurchfluss Q4: 90 m3/h Dauerdurchfluss Q3: 50 m3/h Übergangsdurchfluss Q2: 0.4 m3/h Kleinster Durchfluss Q1: 0.15 m3/h Kleinste ablesbare Menge: 0.5 l Registrierfähigkeit: 1 Mio m3 Messprinzip: Woltman-Turbine Messbereich Lieferkennzeichnung: R 100

94604

PMW-basic 32 10._260_1 G1 / 4; Multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 260 mm Mounting position: horizontal Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0.1 m³ / h Permanent flow Q3: 10 m³ / h Maximum flow Q4: 12.5 m³ / h Kvs-value: 12.7 m³ / h Pressure loss in Q3: 600 mbar Measuring range: R 100 Inlet section: 0 x DN 32 Outlet flow: 0 x DN 32 Degree of protection: IP 66 Approval MI-001

94606

PMWF-basic 32 10._150_1 G1 / 4 multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 150 mm Mounting position: vertical falling Pipe meter Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0.1 m³ / h Permanent flow Q3: 10 m³ / h Maximum flow Q4: 12.5 m³ / h Kvs-value: 10.3 m³ / h Pressure loss in Q3: 900 mbar Measuring range: R 100 Inlet section: 0 x DN 32 Outlet flow: 0 x DN 32 Degree of protection: IP 66 Approval MI-001

94607

PMW-basic 16._300_1 40 1/2 ''; Multi-jet vane hot water meter in glanded Thread connection: G 1 " Nominal size: DN 40 Mounting length: 300 mm Mounting position: horizontal Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0.16 m³ / h Permanent flow Q3: 16 m³ / h Maximum flow Q4: 20 m³ / h Kvs-value: 25.6 m³ / h Pressure loss in Q3: 400 mbar Measuring range: R 100 Inlet section: 0 x DN 40 Outlet flow: 0 x DN 40 Degree of protection: IP 66 Approval MI-001

94608

PMWS-basic 16._200_1 40 1/2 ''; Multi-jet vane hot water meter in glanded Connection thread: G 2 " Nominal size: DN 40 Mounting length: 200 mm Mounting position: vertical ascending Riser counter Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0,16m³ / h Permanent flow Q3: 16 m³ / h Maximum flow Q4: 20 m³ / h Kvs-value: 20.8 m³ / h Pressure loss in Q3: 600 mbar Measuring range: R 100 Inlet section: 0 x DN 40 Outlet flow: 0 x DN 40 Degree of protection: IP 66 Approval MI-001

94609

PMWF-basic 16._200_1 40 1/2 ''; Multi-jet vane hot water meter in glanded Connection thread: G 2 " Nominal size: DN 40 Mounting length: 200 mm Mounting position: vertical falling Pipe meter Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0,16m³ / h Permanent flow Q3: 16 m³ / h Maximum flow Q4: 20 m³ / h Kvs-value: 22.2 m³ / h Pressure loss in Q3: 600 mbar Measuring range: R 100 Inlet section: 0 x DN 40 Outlet flow: 0 x DN 40 Degree of protection: IP 66 Approval MI-001

96166.

CE test water meter R49 DN15-32

96167

CE test water meter R49 DN40-50

ART.NO. 80113/2008 AQUAPULS 1L

Electronic reading system IP68

ART.NO. 83527 RV1/RD 20

Last crop per meter

ART.NO. 92048 VZO 20 RC 130/16-RV1

CONTOIL® oil meter VZO 20 RC 130/16-RV 1 Ring piston meter for mineral oil, with rotatable roller counter